APARATE DE MASURA SI REGLARE PENTRU PH SI REDOX

Transmitter/Controller for pH, ORP, NH3 (ammonia) concentration and temperature (20.2560)
* Directly switchable to pH, ORP or NH3 (ammonia) concentration
* Automatic temperature compensation
* Large LC graphics display with background lighting
* Choice of display mode: large numbers, bar graph or trend display
* Solder-free connection system
* Calibration options according to measured variable: 1-/2-/3-point calibration
* Calibration logbook
* Impedance measurement can be activated for pH measurement
* Symmetrical and asymmetrical connection of pH sensors
* pH-ISFET sensors can be connected thanks to the sensor supply integrated in the output
* IP67 protection (in wall-mounting housing) IP65 protection (for panel mounting)
* Language changeover: German, English, French; further languages can be loaded through the setup program
* Using the setup program: user-friendly programming, plant documentation, additional languages can be loaded


Transmitter / Controller for redox potential (20.2535)
* Panel-mounting instrument, just 96 x 48 x 110 mm
* Display in mV
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width/pulse frequency output or modulating controller
* 2 electrically isolated analog outputs 0(4) - 20 mA / 0(2) - 10 V freely selectable and scalable for redox
* 2 logic inputs
* Monitoring and displaying temperature of medium is possible
* Simple, step-by-step calibration procedure
* OPTION: Profibus-DP or serial interface RS485 / 422 with Modbus/Jbus protocol
* Surface-mounting housing to DIN 43 700, front protection IP65
* Wall-mounting housing protected to IP67


2-wire transmitter for pH / redox combination electrodes (20.2701)
Type 202701 for pH
The 2-wire transmitter converts the high-impedance signal of the pH electrode (up to 1000MOhm) into a standard 4-20 mA signal.
Type 202702 for redox
The 2-wire transmitter converts the signal of the redox electrode into a standard 4-20 mA signal.


Transmitter / Controller for pH or redox potential (20.2530)
* Panel-mounting instrument, just 96 x 48 x 110 mm
* Display pH or mV/ORP and temperature
* Switchable from pH to mV/ORP (redox potential)
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width/pulse frequency output or modulating controller
* 2 electrically isolated analog outputs 0(4) - 20 mA / 0(2) - 10 V freely configurable as process value output for pH, redox or temperature, or for continuous controllers (option)
* 2 logic inputs
* Temperature of medium can be monitored
* Simple, step-by-step calibration procedure
* OPTION: Profibus-DP or serial interface RS485/422 with Modbus/Jbus protocol
* Panel-mounting housing to DIN 43 700, front protection IP65
* Wall-mounting housing: IP67 protection


Indicator / Controller for analytical measurement, bezel size 96 x 48mm (20.2550)
* Panel-mounting unit, just 96 x 48 x 110 mm
* Display of pH, mV, µS/cm, mS/cm, mg/l, etc
* 2 isolated process value outputs 0(4) - 20 mA / 0(2) - 10 V, freely selectable and scalable for the main variable or temperature, or proportional controller (option)
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width or pulse frequency output, or as modulating controller
* 2 logic inputs
* OPTION: Profibus-DP or serial interface RS485 /422 with MODbus /Jbus protocol
* Protection IP65
* Wall-mounting housing, Protection IP65


Portable, microprocessor controlled, digital pH- / redox- and conductivity meters (20.2710)
* MIN and MAX memory
* "Hold" function
* Adjustable automatic switch-off
* Easy-to-read, 2-line LC display
* Supply from a 9 V block battery
* Display of battery condition
* Compact design




APARATE DE MASURA SI REGLARE PENTRU CONDUCTIVITATE SI APA PURA

Transmitter/Controller for conductivity, TDS, resistivity and temperature (20.2565)
* Direct changeover to:
- conductivity (µS/cm or mS/cm)
- resistivity (k x cm or M x cm)
- TDS measurement (ppm or mg/l)
- customer-specific table
* Automatic temperature compensation:
off (e.g. USP), linear, ASTM, natural water (EN 27888/ISO 7888)
* Large LC graphics display with background lighting
* Choice of display: large numbers, bar graph or trend display
* Calibration options according to measured variable: cell constant and temperature coefficient
* Calibration logbook
* Two-electrode cells (as standard) or four-electrode cells can be connected
* Pollution detection can be activated
* Auto-range operation
* IP67 enclosure protection (in wall-mounting housing)
IP65 enclosure protection (for panel mounting)
* Language changeover:
German, English, French; further languages can be loaded through the setup program
* Using the setup program: user-friendly programming, plant documentation, additional languages can be loaded


Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts (20.2756)
* Activation of up to four ranges
* Activation of up to four temperature coefficients
* Concentration measurement of:
- caustic soda NaOH
- nitric acid HNO3
- a freely definable curve (through the setup program)
* Fast-response temperature sensor
* Temperature compensation
- linear
- natural water
- specific characteristic (learning function)
* Operation:
- via keypad and LC display
- through setup program
* Operator languages: English, French, German, Italian, Dutch, Polish, Portuguese, Russian, Spanish, Swedish
* By using the setup program:
- user-friendly programming
- plant documentation
* Learning function for the temperature coefficient
* Individual characteristic for concentration indication
* Dilution control


Transmitter / Controller for high-purity water (20.2545)
* Temperature compensation as per ASTM D-1125-95
* Fulfils the requirements of USP
* Additional linear compensation is possible
* Display of uncompensated conductivity is possible
* Compact design, only 96 x 48 x 110 mm
* Monitoring of the medium temperature is possible
* 2 electrically isolated analog process outputs 0(4) - 20 mA / 0(2) - 10 V, freely selectable and scalable for conductivity or temperature (option)
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width / pulse frequency output or modulating controller
* 1 logic output (alarm contact or temperature limit contact)
* Front protection IP 65
* IP65 surface mounting or site housing on request


Microprocessor transmitter/switching device for conductivity or resistivity and temperature (20.2732)
* Display units µS/cm, mS/cm, kOhm*cm, MOhm*cm, µmho/cm, mmho/cm
* Two parallel signal outputs for conductivity and process temperature 0(4)-20mA / 0(2)-10V; freely programmable
* Switching output (relay changeover contact or, alternatively, two open-collector outputs)
* USP switching function according to USP<645> for use in water installations for pharmaceutical applications
* Temperature compensation is selectable: natural water to EN 27 888, ASTM D 1125-95 (high-purity water), linear
* 3-way isolation (input, output and supply are electrically isolated from each other)
* DIN rail mounting
* Calibration timer
* Customer-specific characteristic for temperature probe can be implemented (NTC or PTC)
* Reference temperature can be set (10-25-40 °C)
* Calibration certificate included in delivery


Portable, microprocessor controlled, digital pH- / redox- and conductivity meters (20.2710)
* MIN and MAX memory
* "Hold" function
* Adjustable automatic switch-off
* Easy-to-read, 2-line LC display
* Supply from a 9 V block battery
* Display of battery condition
* Compact design


Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts (20.2755)
* Activation of up to four ranges
* Activation of up to four temperature coefficients
* Concentration measurement of:
- caustic soda NaOH
- nitric acid HNO3
- a freely definable curve (through the setup program)
* Fast-response temperature sensor
* Temperature compensation
- linear
- natural water
- individual characteristic (learning function)
* Operation
- via keypad and LC display
- through setup program
* Operator languages: English, French, German, Italian, Dutch, Spanish, Polish, Portuguese, Russian, Swedish
By using the setup program:
- user-friendly programming
- plant documentation
* Learning function for the temperature coefficient
* Individual characteristic for concentration indication
* Dilution control


Transmitter / Controller for electrolytic conductivity (20.2540)
* Panel-mounting instrument, just 96 x 48 x 110 mm
* Conductivity display (in µS/cm or mS/cm) and temperature
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width/pulse frequency output or modulating controller
* 2 electrically isolated analog outputs 0(4) - 20 mA / 0(2) - 10 V freely selectable and scalable for conductivity or temperature (option)
* 2 logic inputs
* Monitoring the temperature of the medium is possible
* Calibration procedure for the relative cell constant and temperature coefficient of solution being measured
* OPTION: Profibus-DP or serial interface RS485/422 with Modbus/Jbus protocol
* Measurement ranges from 0 - 0.5 µS to 0 - 200mS in one instrument


Indicator / Controller for analytical measurement, bezel size 96 x 48mm (20.2550)
* Panel-mounting unit, just 96 x 48 x 110 mm
* Display of pH, mV, µS/cm, mS/cm, mg/l, etc
* 2 isolated process value outputs 0(4) - 20 mA / 0(2) - 10 V, freely selectable and scalable for the main variable or temperature, or proportional controller (option)
* 2 relays as standard, freely programmable as limit controller or P, PI, PID, PD controller with pulse width or pulse frequency output, or as modulating controller
* 2 logic inputs
* OPTION: Profibus-DP or serial interface RS485 /422 with MODbus /Jbus protocol
* Protection IP65
* Wall-mounting housing, Protection IP65


Microprocessor transmitter/switching device for conductivity (20.2731)
* 3-way isolation (input, output and supply are electrically isolated from each other)
* DIN rail mounting
* 1 electrically isolated analog output 0(4) - 20 mA / 0(2) - 10 V (Type JUMO ecoTRANS Lf 01)
* 1 relay (Type JUMO ecoTRANS Lf 02)
* Teach-in function (definition of switching point through the teach-in connector) on the JUMO ecoTRANS Lf 02
* 1 LED, two colors (red/green), for signaling operating states
* Calibration timer
* Customized characteristic for temperature probe can be implemented (e.g. NTC, PTC)
* Reference temperature is settable


Inductive conductivity transmitter CTI-Junior (20.2754)
* Inductive conductivity measuring cell
* Material of the conductivity cell: PVC, PVDF or PEEK
* Isolated, hermetically sealed transducer with integral Pt100 for temperature acquisition/correction of the conductivity measurement
* Operating temperatures of the cell material: - 55°C max. with PVC, - 120°C max. with PVDF or PEEK (briefly up to 140°C, e.g. for steam sterilization)
* Max. operating pressure 10 bar
* 3 ranges selectable via rotary switch
* Ranges from 0-1 mS/cm up to 0-500 mS/cm
* Adjustable temperature coefficient




APARATE DE MASURA SI REGLARE PENTRU OXIGEN

Transmitter / Controller for dissolved oxygen (DO) with isolated operating unit (20.2610)
* Measurement of dissolved oxygen (DO) in aqueous solutions
* Safe single-point calibration
* Two-wire transmitter (with basic and standard versions)
* Electrical isolation of measurement signal (DO) and output signal (mA)
* Problem-free linking to an existing installation (e.g. PLC)
* The full (maximum) version provides a stand-alone solution
* Compensation of temperature, atmospheric pressure and salinity
* Further processing of the temperature of the medium possible (separate Pt1000 and two-wire transmitter)
* Setup program provides convenient transmitter configuration/documentation
* Simpler, safer servicing by replacing modules
* Backlit display, i.e. easy to read even in darkness (for the maximum version)
* Comprehensive range of accessories




SISTEME DE MONITORIZARE SI INREGISTRARE

Multiparameter acquisition system for analytical measurement, bezel size 144 x 144mm (20.2595)
* Recording functions: diagrams, event traces, event list
* Evaluation of archived data through the PC evaluation program
* Measurement data are retained, even after a power interruption
* Freely programmable inputs
* Counters and integrators (option)
* Instrument configuration from the keys or through the setup program (diskette or serial interface)
* pH/ redox measurement:
Connection of conventional pH and redox electrodes via 2-wire transmitter or impedance converter, Menu-led calibration of the sensors, 1-, 2- or 3-point calibration, Automatic temperature compensation
* Conductivity measurement:
Connection of conductive and inductive measuring cells via standard signal, Calibration of cell constants and temperature coefficient, Automatic temperature compensation, Non-linear concentration curves are integrated (H2SO4, HNO3, NaOH, etc.), High-purity water measurement according to ASTM and USP
* Free chlorine, chlorine dioxide and ozone measurement:
Connection of the measuring cells via current (or voltage) signal, Cell calibration, pH and temperature-compensated chlorine measurement
* For all measurement inputs:
Evaluation of the electrode condition in plain text (depending on the process variable), Logbook on calibration procedures and sensor ageing




SENZORI PENTRU MARIMI ELECTROCHIMICE SI TEMPERATURA

Gas-sensitive sensor for measuring ammonia (20.1030)
This sensor can be used to measure ammonia (NH3) in aqueous solutions. The ammonia sensor consists of a pH glass electrode and a reference electrode. Both electrodes are in an electrolyte.
The electrolyte is separated from the sample medium by means of a hydrophobic, gas-permeable membrane. The pH of the electrolyte changes if NH3 gas diffuses through the membrane. This local change in pH is measured by the pH electrode as a high-resistance value.


BlackLine pH and redox combination electrodes versions with glass or plastic shaft (20.1005)
Electrodes in the JUMO ecoLine und JUMO BlackLine series are high-quality measuring sensors with an optimum price/performance ratio. Active pH element: JUMO ecoLine electrodes have been manufactured using the JUMO U glass that has proved itself for many years. JUMO BlackLine electrodes are equipped with the lowresistance JUMO UW glass. This guarantees fast and safe measurement results.
Active redox element: A robust platinum tip ensures reliable measurements and allows simple cleaning of the sensor. Reference system: The acrylamide-free JUMO gel is used for the glass version and the PEI plastic version. This highly viscous KCI solution lends itself ideally to measurements in general acqueous media.
For measurements in media containing few ions, or with high flow rates, the electrolyte can be equipped with an optional “salt reservoir” for a longer operational life. The JUMO BlackLine model employs a polymerized KCl solid electrolyte. The JUMO cartridge-type conduction system – tried and tested for many years – is used as the reference system. So the electrolyte remains free from silver ions and therefore less susceptible to electrode poisons.
In the glass shaft version (1), JUMO ecoLine electrodes feature a ceramic diaphragm. The model with plastic shaft in transparent PEI (2) comes with a glassfiber diaphragm. A push-on proctection basket protects the sensor when used with handheld measuring equipment. The JUMO BlackLine (3) has an open annular-gap diaphragm, the shaft is made from black PPO and features an integral protection basket.
The electrodes can optionally be supplied in a storage receptacle, which is recommended if the sensors are only used sporadically, for refreshing them after lengthy and intensive use, or if stored for an extended period. All sensors can be supplied as OEM versions to special order.


Measuring cells for free chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid (20.2630)
* 2- or 3-electrode principle
* easy calibration
* integrated temperature compensation
* proven measuring system


Electrolytic conductivity cells (20.2923)
* 2-electrode principle
* proven versions for industrial application
* measuring ranges: 0-1 mS/cm (K=0.1) or 0.01-15 mS/cm (K=1.0)
* temperature range up to 55°C, maximum pressure: 6 bar at 20°C


Electrolytic conductivity cells, industrial version with graphite electrodes (20.2925)
* 2-electrode system
* cell constant K=1.0; 3.0 or 10.0
* for ranges up to 200mS/cm
* different process connections enable optimal adaptation to process conditions


pH and Redox Combination Electrodes for laboratory measurements with glass or plastic shaft (20.1030)
These electrodes are high-quality sensors for pH and redox potential (ORP) measurements in the laboratory.
The sensors can be supplied with either a glass shaft or a sturdy plastic shaft.
These electrodes are suitable for all measurements in liquid media. They offer a high degree of measurement accuracy and reliability for all applications. A special electrode is available for the ion-selective measurement of ammonia, see page 11.
Suitable models are available for the most diverse requirements:
Active component for pH: There is a choice of different membrane glasses for the pH versions.
Active component for redox: A sturdy platinum or gold tip can be supplied.
Reference system: The tried and tested JUMO silver/silver chloride conductive system (Ag/AgCl) and the acrylamide-free KCl gel together constitute the reference system.
The conductive system is designed in cartridge style. As a result, the reference electrolyte remains free from sliver ions over the entire life span of the sensor, which makes it less susceptible to electrode poisons.
Diaphragm: In the standard version, JUMO labLine electrodes feature a sturdy ceramic diaphragm in zirconium dioxide. On the models with a plastic shaft, a glass fiber diaphragm forms the connection between the substance being measured and the reference system. PTFE and ground diaphragms are available for special applications.
Electrical connection: The electrical connection of the sensors is made through:
- S6 plug cap
- plug cap with attached cable


tecLine Rd pH and redox combination electrodes with glass or plastic shaft (20.1020)
JUMO tecLine electrodes are high-quality sensors for professional application in process and industrial measurement technology. The use of materials and components that meet the highest standards is the distinguishing feature of these electrodes.
They are designed as combined electrodes (the glass or metal electrode and the reference electrode are combined in a single shaft). Depending on the type, a temperature probe can additionally be integrated (option).
Suitable models are available for the most diverse requirements:
JUMO tecLine
- for industrial and municipal water and wastewater engineering
- for measurement in suspensions and varnishes
- for measurement in low-ion media
- for high-alkaline / high-temperature and sterilization processes
- for media containing fluorides and for low-temperature applications
- PRO version for the toughest operating conditions


BlackLine Lf-GT/-EC Electrolytic 2-electrode conductivity cells (20.2922)
* for universal application, e.g. drinking and surface water monitoring, ion exchangers and reverse osmosis plant, construction of air conditioning and cooling systems, horticultural technology, sea water and fresh water aquaculture, mildly contaminated industrial rinse and process water, high-purity water monitoring, etc.
* compact style for universal application
* manufactured from physiologically safe materials


tecLine Lf-VA Electrolytic conductivity cells in stainless steel or titanium (20.2924)
* 2-electrode system
* for ranges from 0.05 µS/cm to 1 mS/cm
* large variety of process connections
* rugged construction
* version for pharmaceutical requirements can be supplied
* shaft diameter 16 mm (with version 202924/20-...)


pH glass electrodes, Redox metal electrodes, Reference electrodes, Diaphragm tubes, Compensation thermometers, Glass conductivity cells (20.1080)
pH glass electrodes:
pH glass electrodes are used in conjunction with reference electrodes for measuring the pH value.
Reference electrodes:
Reference electrodes have the task of providing a constant potential for potentiometric measurements. The potential of an indicator electrode (e.g. a pH glass electrode) serves as the counterpoint.
Redox metal electrodes:
Metal electrodes consist of a glass or plastic shaft that has a metal pin or metal tip fused or glued into the lower end. Metal electrodes are used to determine the redox potential of aqueous media, in conjunction with reference electrodes.
Diaphragm tubes:
Due to physical and/or chemical interactions between sample medium and reference system, potentiometric measurements can be disturbed or falsified by electrochemical sensors. In such cases, it is advisable to use an electrolyte bridge, which is set up with the help of a diaphragm tube.
Compensation thermometers:
Temperature errors may falsify the measurement signal during electrochemical measurements. Measurement errors due to temperature can be compensated by using compensation thermometers.
Glass conductivity cells:
Glass conductivity cells are used to determine the electrolytic conductivity of aqueous solutions. The cells have the cell constant K = 1.0 1/cm




ARMATURI PENTRU SENZORI (PENRTRU PH / REDOX)

Flow-through fittings series 202810 (20.2810)
TFlow-through fittings are used for holding electrochemical sensors (e.g. pH and redox combination electrodes, glass conductivity cells, compensation thermometers etc.) with a Pg13.5 screw-in thread and 120 mm mounting length.
Fitting types for 1 to 3 sensors are available.
The fittings are mounted directly in the liquid flow lines, or in a bypass pipe. They protect the built-in sensors against breakage and, because of their special style, enable the correct flow that is required to avoid measurement errors.
A variety of mounting options and materials are available, but different versions and materials can also be supplied on request.


Manual quick-change fittings series 202822 (20.2822)
* measurements in closed liquid cycles, e.g. pH measurement in cooling and water purification plants
* measurements in closed containers and tanks
* final pH check in outflow, if a bypass is not possible
* Type 202822/106-135-..
fitting with screw-in thread G1A, for installing one sensor with a Pg 13.5 thread and a mounting length of 225 mm
* Type 202822/105-62-..
fitting with screw-in thread G3/4A, for installing one sensor with a Pg 13.5 thread and a mounting length of 120 mm
* Type 202822/613-48-26
fitting with clamp connection, for fitting one sensor with a Pg 13.5 thread and a mounting length of 120 mm


Immersion fittings series 202820 (20.2820)
Immersion fittings are used for holding electrochemical sensors (e.g. pH and redox electrodes, glass conductivity cells, compensation thermometers etc.) with a Pg13.5 screw-in thread and a fitting length of 120mm.
Fitting types for up to 3 sensors are available.
The fittings are mounted in open sluices or containers. They protect the installed sensor from breaking and enable measurement in different immersion depths. Thanks to various options and accessories, the fittings can be optimally adjusted to the conditions on site.
Two pipe clips for wall mounting are provided for the standard versions, but sliding flanges, which are available as an option, also permit installation in container lids, for example.


Process fittings in stainless steel (20.2825)
These fittings are used for holding and protecting sensors. They can either be fitted directly into existing stainless steel pipe systems or onto container walls.
Type 202825 fittings are mainly installed in industrial plants with increased hygienic requirements. The wetted components and the sealing material used are approved by the FDA (Food and Drug Administration).
Type 202831 fittings are predominantly used in water management and in process engineering. Both types of fittings are intended to accomodate sensors of 120 mm length. Other lengths to special order.




SISTEME DE MASURA PT CLOR, DIOXID DE CLOR, APA OXIGENATA, ACID PARACETIC

Measuring cells for free chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid (20.2630)
* 2- or 3-electrode principle
* easy calibration
* integrated temperature compensation
* proven measuring system




ACCESORII

Impedance converter for combination electrodes (20.2995)
* independent of mains supply
* retrofitting is possible
* enables longer cable distances
* stabilizes signal


Accessories pH, redox potential and conductivity measurement (20.1090)




Copyright 2011 © Messystech srl
Gama foarte larga de produse in domeniul tehnicii de masurare si reglare, consultanta de specialitate, service in garantie si postgarantie.
Produsele noastre se aplica intr-o gama variata de domenii: industria energetica, industria chimica, industria alimentara, industria farmaceutica.
Aparate masura si control, manometre, traductoare, termometre, termostate, filtre, reductoare, inregistratoare, instrumente de afisare, presostate, termocuple, regulatoare,
vane, valve, robinete, senzori si aparate de masurare a temperaturii si umiditatii, regulatoare si tehnica de sistem, regulatoare in doua si trei puncte, programatoare,
circuite de masurare electrochimice, stabilizatoare de presiune comutatoare de presiune si comutatoare de presiune diferentiala, manometre in carcasa de otel si otel inox.